Skip to search boxSkip to navigationSkip to main content

Reference values of spirometry parameters in healthy workers at different altitude levels in Peru

Original title: Valores referenciales de los parámetros espirométricos en trabajadores sanos de diferentes niveles de altitud en el Perú
Research Output:
Contribution to journal
Article
Peer-review

Open access

Publication Information

Output type

Research Output:
Contribution to journal
Article
Peer-review

Original language

Spanish

Pages from-to (Number of pages)

Pages 455-462 (8 pages)

Journal (Volume, Issue Number)

Acta Medica Peruana (Volume 37, Issue 4)

Publication milestones

  • Published - 10/2020

Publication status

Published - 10/2020

ISSN

1018-8800

Publication IDs

  • Scopus: 85182298117

Abstract

Objective: to estimate reference values for spirometry parameters in healthy workers at different altitude levels in Peru. Materials and methods: we performed a secondary analysis of records from occupational medical examinations carried out between May and June 2019 in workers at four different altitude levels: level 1: 0-100 m above sea level (ASL) (Trujillo, Pisco, Marcona, Lima), level 2: 2.300-2.800 m ASL (Arequipa and Cajamarca), level 3: 3.200-3.800 m ASL (Huancayo, La Oroya, Orcopampa, and Oyon); and level 4: 4.000-4.400 m ASL (Carhuacoto and Cerro de Pasco). Spirometry reference values for forced expiratory volume during the first second (FEV1), forced vital capacity (FVC), and the FEV1/FVC rate were constructed and compared using a multiple linear regression model. Results: we analyzed 33.232 records obtained from healthy workers in different altitude levels in Peru. In male subjects, FVC values were 4,6 ± 0,64 (mean ± standard deviation [SD]); 4,8 ± 0,67; 4,9 ± 0,65; and 4,8 ± 0,65 for altitude levels 1, 2, 3, and 4, respectively. Their corresponding lower limit of normal (LLN) values were 3,58; 3,78; 3,84; and 3,75 for altitude levels 1, 2, 3, and 4, respectively. FEV1 values were 3,8 ± 0,54; 3,9 ± 0,59; 4,0 ± 0,57; and 4,0 ± 0,59 for altitude levels 1, 2, 3, and 4, respectively. Their corresponding LLN values were 2,93; 3,06; 3,13; and 3,08 for levels 1, 2, 3, and 4, respectively. FEV/FVC rates were 0,83 ± 0,05; 0,83 ± 0,05; 0,84 ± 0,05; and 0,84 ± 0,05 for altitude levels 1, 2, 3, and 4, respectively. Their corresponding LLN values were 0,72; 0,71; 0,71; and 0,72 for altitude levels 1, 2, 3, and 4, respectively. Conclusions: both FEV1 and FVC spirometry values show mild differences according to altitude levels in the different evaluated areas. Further studies are necessary aiming to confirm our findings.

Publication metrics

Metrics

Scopus
Citations

PlumX, opens in new tab

Social media
44
Citations
1
Captures
12