Skip to search boxSkip to navigationSkip to main content

Level of patient comfort and measurement reproducibility of three different probes: A cross-sectional study

  • Daisy Flores-Rodrigo
    ,
  • Jonathan Meza-Mauricio
    ,
  • Belen Retamal-Valdes
    ,
  • ,
  • Gerardo Mendoza-Azpur
Research Output:
Contribution to journal
Article
Peer-review

Publication Information

Output type

Research Output:
Contribution to journal
Article
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 301-307 (7 pages)

Journal (Volume, Issue Number)

International Journal of Dental Hygiene (Volume 20, Issue 2)

Publication milestones

  • Accepted/In press - 2021
  • Published - 05/2022

Publication status

Published - 05/2022

ISSN

1601-5029

Publication IDs

  • Scopus: 85113622603

Abstract

Objective: To determine the comfort level and reproducibility assessment of the probing pocket depth obtained with three different probes. Methods: A cross-sectional clinical study was conducted in accordance with the STROBE standards. Three different types of periodontal probes were selected: (1) University of North Carolina (UNC) probe, (2) World health organization (WHO) probe and (3) UNC12 COLORVUE probe. Three experienced and calibrated periodontists performed periodontal clinical assessments (probing depth) and pain assessment with the visual analogue scale (VAS). Results: The clinical evaluations were carried out in 13 volunteers who attended the dental clinic of the Universidad Científica del Sur (Lima, Peru). A total of 2106 periodontal clinical measurements were obtained (702 measurements per examiner). Each examiner evaluated 234 sites for each type of probe. When patient comfort values during the periodontal evaluation performed with the 3 types of probes were compared, the patients evaluated with the UNC12 COLORVUE probe perceived less pain with a mean value of 0.61, followed by the WHO probe and the UNC probe. When evaluating the clinical measurements, the UNC probe was observed to obtain the greatest mean depth on probing 1.4 + 0.5 mm, while with the UNC12 Colorvue probe, the values obtained were 1.1 + 0.3 mm, and with the WHO probe, 1.2 + 0.4 mm. Conclusions: Based on the periodontal probe used, experience of the examiner and the patient, we can conclude that the UNC12 Colorvue probe was the instrument that promoted the greatest comfort or the slightest response to pain, followed by the WHO probe. However, the use of the WHO probe resulted in obtaining the lowest reproducibility among depths on probing. The UNC probe produced the highest response to pain in the patients.

Funding Details

The authors gratefully acknowledge the contribution of the evaluators Carmen Castro Ruiz, Dennis La Torre; and of all participants who completed the questionnaire.