Skip to search boxSkip to navigationSkip to main content

Fracture Resistance of Cement-retained, Screw-retained, and Combined Cement- and Screw-retained Metal-ceramic Implant-supported Molar Restorations

  • Violeta Malpartida-Carrillo(corresponding author)
    ,
  • ,
  • Fernando Ortz-Culca
    ,
  • Maria E. Guerrero
    ,
  • Silvia P. Amaya-Pajares
    ,
  • Mutlu Özcan
*Corresponding author for this work
  • Universidad Científica del Sur
    ,
  • ,
  • Universidad Nacional Mayor de San Marcos
    ,
  • Oregon Health & Science University
    ,
  • University of Zurich
Research Output:
Contribution to journal
Article
Peer-review

Open access

Publication Information

Output type

Research Output:
Contribution to journal
Article
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 868-873 (6 pages)

Journal (Volume, Issue Number)

Journal of Contemporary Dental Practice (Volume 21, Issue 8)

Publication milestones

  • Published - 01/01/2020

Publication status

Published - 01/01/2020

Publication IDs

  • Scopus: 85097863340
  • PubMed: 33568607

Abstract

Aim: To compare fracture resistance between the cement-retained (CR), screw-retained (SR), and combined cement- and screw-retained (CCSR) metal-ceramic (MC) implant-supported molar restorations and the fracture mode after vertical loading simulation. Materials and methods: Thirty MC molar restorations were fabricated on thirty tilted dental implants that were repositioned using prefabricated or universal castable long abutments (UCLA) with 15° of angulation divided into three groups of ten specimens each. Group C: CR, group S: SR, and group CS: cement- and screw-retained. The crowns in group CS were adhesively bonded extraorally, and composite resin was used to fll the screw access holes (SAHs) in groups S and CS. Subsequently, all the specimens were tested for fracture resistance. A scanning electron microscope (SEM) evaluation of the fracture mode was also performed. Mean values of fracture loads were calculated and compared in Newtons (N) using one-way ANOVA and Tukey post hoc test (p < 0.05) for each group. Results: Mean fracture load values were 2718.00 ± 266.25 N for group C, 2125.10 ±293.82 N for group S, and 2508.00 ±153.59 N for group CS. Significant differences were found between group S and the other groups on fracture load values. However, no significant differences were found between groups C and CS (p = 0.154). The failures were at MC framework interfaces on mesiolingual cusps. Conclusions: Cement and CCSR MC molar restorations showed comparable fracture resistance using abutments with 15° of angulation. However, SR design showed significantly the lowest values of resistance. Screw access hole did not significantly afect the fracture resistance of cemented MC molar restorations. All the specimens exhibited mixed adhesive fractures at the mesiolingual cusps. Clinical significance: Combined cement- and screw-retained restorations (CCSRRs) incorporate the simplicity of the cement method and the retrievability of the screw method, offering good resistance, allowing the removal of the excess of cement before clinical placement of the restoration, and providing another alternative for dental implant rehabilitation.