Diagnostic performance of RT-PCR-based sample pooling strategy for the detection of SARS-CoV-2
- Miguel Hueda-Zavaleta(corresponding author),
- Cesar Copaja-Corzo,
- Vicente A. Benites-Zapata,
- Pedro Cardenas-Rueda,
- ,
- Alfonso J. Rodríguez-Morales(corresponding author)
- Hospital III Daniel Alcides Carrión,
- Universidad Privada de Tacna,
- Universidad San Ignacio de Loyola,
- ,
- ,
- Fundacion Universitaria Autonoma de las Américas
Open access
Publication Information
Output type
Original language
EnglishArticle number
11Journal (Volume, Issue Number)
Annals of Clinical Microbiology and Antimicrobials (Volume 21, Issue 1)Publication milestones
- Published - 12/2022
Publication status
Publication IDs
- Scopus: 85126223561
Abstract
Background: The rapid spread of SARS-CoV-2 has created a shortage of supplies of reagents for its detection throughout the world, especially in Latin America. The pooling of samples consists of combining individual patient samples in a block and analyzing the group as a particular sample. This strategy has been shown to reduce the burden of laboratory material and logistical resources by up to 80%. Therefore, we aimed to evaluate the diagnostic performance of the pool of samples analyzed by RT-PCR to detect SARS-CoV-2. Methods: A cross-sectional study of diagnostic tests was carried out. We individually evaluated 420 samples, and 42 clusters were formed, each one with ten samples. These clusters could contain 0, 1 or 2 positive samples to simulate a positivity of 0, 10 and 20%, respectively. RT-PCR analyzed the groups for the detection of SARS-CoV-2. The area under the ROC curve (AUC), the Youden index, the global and subgroup sensitivity and specificity were calculated according to their Ct values that were classified as high (H: ≤ 25), moderate (M: 26–30) and low (L: 31–35) concentration of viral RNA. Results: From a total of 42 pools, 41 (97.6%) obtained the same result as the samples they contained (positive or negative). The AUC for pooling, Youden index, sensitivity, and specificity were 0.98 (95% CI, 0.95–1); 0.97 (95% CI, 0.90–1.03); 96.67% (95% CI; 88.58–100%) and 100% (95% CI; 95.83–100%) respectively. In the stratified analysis of the pools containing samples with Ct ≤ 25, the sensitivity was 100% (95% CI; 90–100%), while with the pools containing samples with Ct ≥ 31, the sensitivity was 80% (95% CI, 34.94–100%). Finally, a higher median was observed in the Ct of the clusters, with respect to the individual samples (p < 0.001). Conclusions: The strategy of pooling nasopharyngeal swab samples for analysis by SARS-CoV-2 RT-PCR showed high diagnostic performance.
Funding Details
Access to documents
Publication metrics
Metrics
PlumX, opens in new tab
Sustainable Development Goals
- SDG 3 Good Health and Well
