Skip to search boxSkip to navigationSkip to main content

Assessment of fractures in endodontically treated teeth restored with and without root canal posts using high-resolution cone beam computed tomography

  • David Aristizabal-Elejalde
    ,
  • ,
  • Aron Aliaga-Del Castillo
    ,
  • Gustavo Armando Ruíz-Mora
    ,
  • Yalil Augusto Rodríguez-Cárdenas
  • Universidad Científica del Sur
    ,
  • ,
  • University of São Paulo
    ,
  • Universidad Nacional de Colombia
Research Output: Contribution to journal Article Peer-review

Open access

Publication Information

Output type

Research Output: Contribution to journal Article Peer-review

Original language

English

Pages from-to (Number of pages)

Pages e547-e554

Journal (Volume, Issue Number)

Journal of Clinical and Experimental Dentistry (Volume 12, Issue 6)

Publication milestones

  • Published - 01/06/2020

Publication status

Published - 01/06/2020

Publication IDs

  • Scopus: 85088274154

Abstract

Background: Root fractures are a diagnostic challenge for dentists in endodontic treatment. This study aimed to determine the relationship between the characteristics of tooth fractures and the presence of root canal posts in endodontically treated teeth using high-resolution cone beam computed tomography (CBCT). Material and Methods: Fifty high-resolution CBCT scans of endodontically treated teeth with a diagnosis of fracture were obtained, of which 30 were from women and 20 were from men. These scans were acquired with three Veraviewepocs 3D units and one 3D Accuitomo 170 unit, with a 40 x 40-mm field of view and 125 μm voxel size. The variables assessed included the type of fracture, extent of fracture, type of retention, post length, cause of endodontic failure, location of the lesion, and time required to detect the fracture (difficulty score). For data analysis, the chi-squared test, Student's t-test, and multiple linear regression (α 0.05) were used. Results: No association was found between the type of fracture and type of retention or between the type of fracture and its extent (P 0.05). On the other hand, the type of fracture significantly influenced the time required for its detection. Additionally, the most difficult plane for detecting the fracture and the difficulty score were associated, with statistically significant results. Conclusions: The type of fracture in endodontically treated teeth was not associated with the type of post used for restoration. All of the CBCT systems used to detect tooth fracture showed the same efficiency.

Publication metrics

Metrics

Scopus
Citations

PlumX, opens in new tab

Citations
1
Captures
39