TY - JOUR
T1 - The interference of digital radiographic image acquisition and processing protocols in the diagnosis of incipient enamel carious lesions
AU - Ribeiro, Patricia Fernandes Avila
AU - Hashizume, Lina Naomi
AU - Arriola-Guillén, Luis Ernesto
AU - Madeira, Kristian
AU - Vizzotto, Mariana Boessio
AU - da Silveira, Heraldo Luís Dias
N1 - Publisher Copyright:
© 2024 Medicina Oral S. L. C.I.F. B 96689336 - eISSN: 1989-5488 eMail: [email protected]. All Rights Reserved.
PY - 2024
Y1 - 2024
N2 - Background: This study aims to evaluate the diagnosis of proximal carious lesions through different parameters of execution and visualization of the images. Material and Methods: Proximal carious lesions were artificially induced in human teeth three different times (10, 20, and 30 hours) by in vitro demineralization. The teeth were radiographed with the Dürr digital system using three exposure times (0.10, 0.16, and 0.20s) and three different resolutions in the scanning of the phosphor plates (20-, 25- and 40-line pairs). After acquiring the images, they were submitted to VistaScan Fine, Caries 1, and Caries 2 software filters. Three radiologists analyzed the images in JPEG format. Results: The Pearson’s chi-square test showed an association between longer demineralization time and the presence of injury according to the professional’s classification. There was no statistically significant association among the other parameters, exposure time, resolution, and use of filters and the presence of a lesion. All parameters showed a greater sensitivity than specificity. The exposure time of 0.2s showed better accuracy, the resolutions 25 and 40lp showed equal results and better than 20lp and the Fine filter obtained better values than the Caries 1 and 2 filters. Conclusions: Despite the variation of parameters, exposure time, resolution, and use of filters, there were no statistically significant differences. For better diagnostic accuracy, it is recommended to use 0.2s of exposure time and a Fine filter, and scan the phosphor plates with 25lp.
AB - Background: This study aims to evaluate the diagnosis of proximal carious lesions through different parameters of execution and visualization of the images. Material and Methods: Proximal carious lesions were artificially induced in human teeth three different times (10, 20, and 30 hours) by in vitro demineralization. The teeth were radiographed with the Dürr digital system using three exposure times (0.10, 0.16, and 0.20s) and three different resolutions in the scanning of the phosphor plates (20-, 25- and 40-line pairs). After acquiring the images, they were submitted to VistaScan Fine, Caries 1, and Caries 2 software filters. Three radiologists analyzed the images in JPEG format. Results: The Pearson’s chi-square test showed an association between longer demineralization time and the presence of injury according to the professional’s classification. There was no statistically significant association among the other parameters, exposure time, resolution, and use of filters and the presence of a lesion. All parameters showed a greater sensitivity than specificity. The exposure time of 0.2s showed better accuracy, the resolutions 25 and 40lp showed equal results and better than 20lp and the Fine filter obtained better values than the Caries 1 and 2 filters. Conclusions: Despite the variation of parameters, exposure time, resolution, and use of filters, there were no statistically significant differences. For better diagnostic accuracy, it is recommended to use 0.2s of exposure time and a Fine filter, and scan the phosphor plates with 25lp.
KW - Etiology
KW - Orbital fracture
KW - Orbital trauma
KW - Road traffic accidents
KW - Trauma
UR - http://www.scopus.com/inward/record.url?scp=85185461712&partnerID=8YFLogxK
U2 - 10.4317/jced.60990
DO - 10.4317/jced.60990
M3 - Artículo
AN - SCOPUS:85185461712
SN - 1989-5488
VL - 16
SP - 96
EP - 103
JO - Journal of Clinical and Experimental Dentistry
JF - Journal of Clinical and Experimental Dentistry
IS - 2
ER -