T1 - Fracture Resistance of Cement-retained, Screw-retained, and Combined Cement- and Screw-retained Metal-ceramic Implant-supported Molar Restorations
AU - Malpartida-Carrillo, Violeta
AU - Tinedo-López, Pedro Luis
AU - Ortz-Culca, Fernando
AU - Guerrero, Maria E.
AU - Amaya-Pajares, Silvia P.
AU - Özcan, Mutlu
N1 - Publisher Copyright:
© The Author(s). 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons. org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
PY - 2020/1/1
Y1 - 2020/1/1
N2 - Aim: To compare fracture resistance between the cement-retained (CR), screw-retained (SR), and combined cement- and screw-retained (CCSR) metal-ceramic (MC) implant-supported molar restorations and the fracture mode after vertical loading simulation. Materials and methods: Thirty MC molar restorations were fabricated on thirty tilted dental implants that were repositioned using prefabricated or universal castable long abutments (UCLA) with 15° of angulation divided into three groups of ten specimens each. Group C: CR, group S: SR, and group CS: cement- and screw-retained. The crowns in group CS were adhesively bonded extraorally, and composite resin was used to fll the screw access holes (SAHs) in groups S and CS. Subsequently, all the specimens were tested for fracture resistance. A scanning electron microscope (SEM) evaluation of the fracture mode was also performed. Mean values of fracture loads were calculated and compared in Newtons (N) using one-way ANOVA and Tukey post hoc test (p < 0.05) for each group. Results: Mean fracture load values were 2718.00 ± 266.25 N for group C, 2125.10 ±293.82 N for group S, and 2508.00 ±153.59 N for group CS. Significant differences were found between group S and the other groups on fracture load values. However, no significant differences were found between groups C and CS (p = 0.154). The failures were at MC framework interfaces on mesiolingual cusps. Conclusions: Cement and CCSR MC molar restorations showed comparable fracture resistance using abutments with 15° of angulation. However, SR design showed significantly the lowest values of resistance. Screw access hole did not significantly afect the fracture resistance of cemented MC molar restorations. All the specimens exhibited mixed adhesive fractures at the mesiolingual cusps. Clinical significance: Combined cement- and screw-retained restorations (CCSRRs) incorporate the simplicity of the cement method and the retrievability of the screw method, offering good resistance, allowing the removal of the excess of cement before clinical placement of the restoration, and providing another alternative for dental implant rehabilitation.
AB - Aim: To compare fracture resistance between the cement-retained (CR), screw-retained (SR), and combined cement- and screw-retained (CCSR) metal-ceramic (MC) implant-supported molar restorations and the fracture mode after vertical loading simulation. Materials and methods: Thirty MC molar restorations were fabricated on thirty tilted dental implants that were repositioned using prefabricated or universal castable long abutments (UCLA) with 15° of angulation divided into three groups of ten specimens each. Group C: CR, group S: SR, and group CS: cement- and screw-retained. The crowns in group CS were adhesively bonded extraorally, and composite resin was used to fll the screw access holes (SAHs) in groups S and CS. Subsequently, all the specimens were tested for fracture resistance. A scanning electron microscope (SEM) evaluation of the fracture mode was also performed. Mean values of fracture loads were calculated and compared in Newtons (N) using one-way ANOVA and Tukey post hoc test (p < 0.05) for each group. Results: Mean fracture load values were 2718.00 ± 266.25 N for group C, 2125.10 ±293.82 N for group S, and 2508.00 ±153.59 N for group CS. Significant differences were found between group S and the other groups on fracture load values. However, no significant differences were found between groups C and CS (p = 0.154). The failures were at MC framework interfaces on mesiolingual cusps. Conclusions: Cement and CCSR MC molar restorations showed comparable fracture resistance using abutments with 15° of angulation. However, SR design showed significantly the lowest values of resistance. Screw access hole did not significantly afect the fracture resistance of cemented MC molar restorations. All the specimens exhibited mixed adhesive fractures at the mesiolingual cusps. Clinical significance: Combined cement- and screw-retained restorations (CCSRRs) incorporate the simplicity of the cement method and the retrievability of the screw method, offering good resistance, allowing the removal of the excess of cement before clinical placement of the restoration, and providing another alternative for dental implant rehabilitation.
KW - Dental casting techniques
KW - Dental implants
KW - Implant-supported dental prosthesis
KW - Metal ceramic alloys
UR - http://www.scopus.com/inward/record.url?scp=85097863340&partnerID=8YFLogxK
U2 - 10.5005/JP-JOURNALS-10024-2884
DO - 10.5005/JP-JOURNALS-10024-2884
M3 - Artículo
C2 - 33568607
AN - SCOPUS:85097863340
SN - 1526-3711
VL - 21
SP - 868
EP - 873
JO - Journal of Contemporary Dental Practice
JF - Journal of Contemporary Dental Practice
IS - 8
ER -