TY - JOUR
T1 - Esthetic and clinical outcomes after immediate placement and restoration
T2 - Comparison of two implant systems in the anterior maxilla—A cross-sectional study
AU - Parvini, Puria
AU - Trimpou, Georgia
AU - Begic, Amira
AU - Cafferata, Emilio A.
AU - Petsos, Hari
AU - Müller, Katharina Melissa
AU - Schwarz, Frank
AU - Eickholz, Peter
AU - Obreja, Karina
N1 - Publisher Copyright:
© 2022 Wiley Periodicals LLC.
PY - 2023/4
Y1 - 2023/4
N2 - Aim: To assess the esthetic and clinical performance of a novel self-tapping implant system for single-tooth restorations in the esthetic zone after immediate placement and provisionalization. Materials and Methods: This cross-sectional study included 52 patients contributing a total of 52 immediately placed and restored implants with ≥12 months after functional loading, comparing two different implant systems: Straumann® BLX (Institut Straumann AG, Basel, Switzerland; 25 patients) and Ankylos® (Dentsply Sirona, Hanau, Germany; 27 patients). As the primary outcome measure, peri-implant tissue esthetics were assessed by means of pink esthetics score (PES) rated by three independent clinicians. Moreover, as secondary outcome measures, the peri-implant tissue health was assessed by means of bleeding on probing, probing depth, and suppuration. Apart from that, the modified plaque index, keratinized mucosa width, and the presence of mucosal recessions were also assessed. When clinical signs suggested the possibility of peri-implantitis, radiographs were indicated to assess progressive bone loss. Results: The mean PES ratings were 12.10 ± 1.10 for Ankylos versus 11.2 ± 1.86 for BLX, both achieving good esthetic results without significant differences (p = 0.143). There were no differences among most clinical parameters (plaque, bleeding on probing, probing depth, peri-implant mucosal recession), although peri-implant mucositis was present in one-third of the cases. The inter-rater agreement on esthetics was not significant (p < 0.250). Conclusion: Within the limitations of the present study, it was concluded that the use of either BLX or Ankylos implant systems was associated to comparable peri-implant health and good pink esthetic outcomes during immediate implantation and restoration protocols, for at least 12 months.
AB - Aim: To assess the esthetic and clinical performance of a novel self-tapping implant system for single-tooth restorations in the esthetic zone after immediate placement and provisionalization. Materials and Methods: This cross-sectional study included 52 patients contributing a total of 52 immediately placed and restored implants with ≥12 months after functional loading, comparing two different implant systems: Straumann® BLX (Institut Straumann AG, Basel, Switzerland; 25 patients) and Ankylos® (Dentsply Sirona, Hanau, Germany; 27 patients). As the primary outcome measure, peri-implant tissue esthetics were assessed by means of pink esthetics score (PES) rated by three independent clinicians. Moreover, as secondary outcome measures, the peri-implant tissue health was assessed by means of bleeding on probing, probing depth, and suppuration. Apart from that, the modified plaque index, keratinized mucosa width, and the presence of mucosal recessions were also assessed. When clinical signs suggested the possibility of peri-implantitis, radiographs were indicated to assess progressive bone loss. Results: The mean PES ratings were 12.10 ± 1.10 for Ankylos versus 11.2 ± 1.86 for BLX, both achieving good esthetic results without significant differences (p = 0.143). There were no differences among most clinical parameters (plaque, bleeding on probing, probing depth, peri-implant mucosal recession), although peri-implant mucositis was present in one-third of the cases. The inter-rater agreement on esthetics was not significant (p < 0.250). Conclusion: Within the limitations of the present study, it was concluded that the use of either BLX or Ankylos implant systems was associated to comparable peri-implant health and good pink esthetic outcomes during immediate implantation and restoration protocols, for at least 12 months.
KW - dental esthetics
KW - dental implants
KW - dental prosthesis
KW - immediate dental implant loading
KW - implant-supported
KW - single-tooth
UR - http://www.scopus.com/inward/record.url?scp=85145280081&partnerID=8YFLogxK
U2 - 10.1111/cid.13158
DO - 10.1111/cid.13158
M3 - Artículo
AN - SCOPUS:85145280081
SN - 1523-0899
VL - 25
SP - 252
EP - 260
JO - Clinical Implant Dentistry and Related Research
JF - Clinical Implant Dentistry and Related Research
IS - 2
ER -