Evaluation of an ozone generation system for the control of microorganisms in the indoor air of sanitary environments Brief Original Article

Judith Yali-Rivera, Katherine Yauri-Condor, Jorge Inolopu-Cucche, Jaime Rosales- Rimache

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Objetive: Evaluate an Ozone Generating System (OGS) through of the microorganisms count and identificated in the air of the sanitary environments of the National Institute of Health (INS) from Peru. The study: These were exposed to OGS for 1 min per m2, air samples were collected at volumes of 200L, 500L and 1000L by impaction, pre and post exposure to OGS, cultures were obtained on Plate Count Agar (PCA) and Oxytetracycline Glucose Agar (OGA) grown at 35°C±2°C for 48 hours and 25°C ± 2°C for 5 days. Findings: A decrease in the count of fungi after exposure to OGS, the difference being statistically significant for the volumes of 200L (p=0.047) and 1000 L (p<0.005); Aspergillus spp. species were identified in most cultures, in bacteria no significant difference was observed. Conclusions: The OGS is a method that inhibits the growth of most fungi in sanitary environments.

Original languageEnglish
Pages (from-to)256-260
Number of pages5
JournalRevista del Cuerpo Medico Hospital Nacional Almanzor Aguinaga Asenjo
Volume15
Issue number2
DOIs
StatePublished - Apr 2022
Externally publishedYes

Keywords

  • air
  • analysis (Fuente: DeCSBIREME)
  • environmental microbiology
  • ozone

Fingerprint

Dive into the research topics of 'Evaluation of an ozone generation system for the control of microorganisms in the indoor air of sanitary environments Brief Original Article'. Together they form a unique fingerprint.

Cite this